Dropped Due To Slot Reservation Cs 1.6 Que Significa

Posted onby admin
  1. Dropped Due To Slot Reservation Cs 1.6 Que Significa En
  2. Dropped Due To Slot Reservation Cs 1.6 Que Significa Se
  3. Dropped Due To Slot Reservation Cs 1.6 Que Significa Es

Counter Strike 1.6 CS Servers 72.5.195.92. During my Army Tenure in Germany i was not allowed to play due to High ping Str8 was cool about it and i dealt with. In AAL1, each cell carries only 47 bytes of user data. This means the number of cells sent per second can be calculated as (2,000,000/8)/47 ≈ 5319.15. In AAL3/4, the CS layer needs to pass 44-byte data units to SAR layer. This means that the total length of the packet in the CS layer should be a multiple of 44. (FAO) problemas ms comunes en Counter Strike 1.6 (CS 1. 6) Holas, como estn? Espero que bien, hoy les voy a traer un faq con los problemas ms comunes en Counter Strike 1.6 compilados por mi. Empecemos: Dropped due to slot reservation Este mensaje nos indica que en el servidor, se encuentra un slot reservado el cual sera usado por un admin o una persona con privilegios para poder ocupar este. Studies on slotted ALOHA (S-ALOHA) systems have a long research history and been quite mature in the literature. However, this thesis revisits S-ALOHA systems by considering multipacket reception (MPR) channels, because previous studies are no longer applicable to MPR capable S-ALOHA systems due to the new random access channels (RACHs) of contemporary wireless cellular network standards.

Summary:A Digitrax term referring to address management by a Digitrax DCC system.

DCC Terms
DCC Components
Accessory Decoder, Auto Reverse, Command station, Computer Interface, Consists, DCC Booster, DCC Ready, Decoder, Digital Packet, How Digital Command Control Works, Multifunction Decoder, Power Supply, Speed Steps, Throttle, XPressNet
General
Address Partitioning, Ammeter, Analog Control of Model Railroads, Bus, Cab, Can Motor, Command Control, Coreless Motors and DCC, DCC, DCC in a Box, DMM, Distributed Power, Frog Juicer, Jump Port, LCC, Layout Command Control, Locomotive, Motor, Multiple Unit Consisting, Original Equipment Manufacturer, Phase, Power Bus, Programming Track, Pulse Width Modulation, Rail Size, Serial User System Interface - SUSI, Slots, Standard Dimensions, Turnout Motors, Turnouts with Digital Command Control, Voltage Drop, Zero Stretching
Mobile decoder
Analog Conversion, Back EMF, Decoder Connection Method, Digitrax Transponding, Ditch Lights, Dither, Energy Storage, FX Lighting, Functions, High-Frequency Decoders, Kick Start, Lenz USP, Lighting Effects, Locomotive Interface, Loco Momentum, Multifunction Decoder Assisted Consisting, NMRA Connector, NMRA DCC Plug for Multifunction Decoders, Power Conversion, Programming Lock, Programming Modes, Quartering, Silent Drive, Snood, XOR
Non-DCC
Continuous Load, FRED, Heat Shrink Tubing, Magic Smoke, RJ12 Connector, Rule 17, Series Resistor, Stall Current
Boosters ·Command Station ·Decoder ·Power Supply ·Throttles/Cabs
Short Definition

A Digitrax term to refer to an address management for locomotives under control by a Digitrax system.

  • 1What are Slots?
    • 1.1Slot Status
      • 1.1.1What Does it Mean?
    • 1.3Slots = MAX Warning
      • 1.3.1Additional Information about the Slots = Max Warning
      • 1.3.2Clearing the Slots
    • 1.4Managing the Slots
    • 1.7Purging Made Easy
    • 1.9Slot Following

What are Slots?

Slot

Slots are a concept used in Digitraxcommand stations. The number of slots available determine how many locomotives you can operate.

The concept is similar to that of a 'heap' used in Computer Science: It is a portion of memory set aside by the program you are running to store variables and frequently used data. In this case, locomotiveaddresses and consist information is stored by the command station's software for use later. Different Digitrax command stations have different amounts of memory available for slots, in the case of the Chief line, the number of slots available can be defined by changing a setting in the command station. The Advanced command stations feature Expanded Slots.

The Zephyr has ten and Zephyr Xtra features 20 slots. The Empire Builder has 22. The Chief and Super Chief have 120 slots. See the Digitrax Command Station Comparison for more info.

Slot Status

A slot can in in one of four states:

  1. In Use: The slot has an assigned throttle, and the command station is sending commands to the track
  2. Common: Commands are being sent; No throttle assigned
  3. Idle: The command station is ignoring this slot, no commands are being sent related to this slot.
  4. Free: Slot is empty or has not been assigned or used. A computer running software can also clear slots.

Any slot while in use which does not receive updates from its associated throttle after a period of time may be marked as Common or Idle. If a slot's status is Common and the speed is set to Zero, the slot may be purged by the command station at a later point in time.

  • If the command station does not receive LocoNet messages in a timely manner due to corrupt messages or other activities demanding time, slots may be set to Common.

What Does it Mean?

Common

A slot labelled Common is being refreshed by the command station, and will not be available for use with another address. An excessive number of common status slots is often a result of operator discipline, or lack thereof. With proper discipline the number of slots with common status can be managed.

Releasing an address sets the status of that slot to common.

If an operator inadvertently selects an incorrect address, that address should be dispatched before a new address selection is attempted. If a new address is entered without dispatching the prior one, the first address will have its slot changed to common. By using Dispatch, the slot is made idle and available for use

Idle

This slot is available for re-assignment to a new address. By using Dispatch the status of the slot is changed to Idle, instead of common.

UniVersal Consists

UniVersal Consisting is the default Digitrax consisting method. Addresses in a consist remain in common status until the address(es) are removed from the consist. This ensures addresses are not removed inadvertently from a consist by reuse of their slot.

Purge

Any address which is permitted to Purge will have its slot status changed to common.

Clearing Slots

It is possible to manually clear slots using the throttle, the typical procedure with an advanced throttle is to select the locomotive address and press EXIT. This is not the same as Dispatching.

Slots = MAX Warning

This warning indicates the maximum number of slots available (or memory set aside for this) has been reached. Until they are cleared out, this message will persist. This can be done using an option switch (see your manual) or JMRI's LocoNet tools.

The main cause of this warning is locomotives which were not dispatched by their operator after an operating session.

Additional Information about the Slots = Max Warning

On a DT400 or DT300, the display will show Slot=Max. Older DT100 or DT200 throttles will display FF, and the Zephyr shows FULL. All these indications mean that the number of slots available is zero, as all are in use.

Zephyr Express

The DCS52 Zephyr Express will display SLOTMAX on the display.

Clearing the Slots

Closing Option Switch 36 clears all slots in the command station (including “UniVersal” consists) currently in the system, leaving all other option switches as set. Once accomplished, the throttle will be able to select addresses again.

The exact procedure varies depending on the command station and throttle you are using, thus you will need to check the section for “Option Switch Setting” in your command station and throttle manuals.

OpSw38 (Obsolete)

OpSw38 clears the Alias Address Roster, a legacy feature allowing the use 4 digit addresses with decoders supporting only short (2 Digit) addresses. The only DT100 throttles can use this feature, which is rarely used today.

Managing the Slots

Dropped Due To Slot Reservation Cs 1.6 Que Significa En

Releasing Individual Locomotives

A common reason for using all the slots in a command station is that locomotives are not properly dispatched when their operators are finished with them. To free a slot used by an individual locomotive, first make sure that the locomotive is removed from any consist that it may be part of. Then select the locomotive on a throttle, set the speed to zero, and dispatch the locomotive (see the throttle manual for instructions on how to dispatch locomotive addresses). This will set the slot to 'free' and it can then be assigned to another locomotive when needed.

Dropped Due To Slot Reservation Cs 1.6 Que Significa

Continue this proceedure for all locomotives that are occupying slots, but which not in use. (it may be difficult to determine which locomotive addresses are occupying slots in the command station)

Setting up the command station and Operator Discipline

  1. Purging makes a slot available for use. Purging requires the throttle be set to “0” (zero) speed and not be part of a UniVersal consist. Setting OpSw 14 to thrown and OpSw 15 to closed ensure all non-consisted individual addresses are purged.
  2. DCS 100/200 only: These command stations have 120 slots, however the factory default is 22 slots. CloseOpSw 44 to make 120 slots available.
  3. Releasing or Dispatching: Ensuring each locomotive's throttle is at “0” (zero) speed and is either released or dispatched.
  4. Consists: “UniVersal” consisted locomotives (Digitrax's default method) will not be purged. Locomotives must be unlinked from their consist to allow these slots to be purged. This is an issue of Operator discipline. If you want permanent consists, consider basic or advanced consisting.
  5. Periodic OpSw 36 clear: Clearing the slots (OpSw 36) helps, especially if UniVersal consists are filling slots.
  6. If you reset OPSW 36 on your command station, all mobile decoderaddresses and MU information will be cleared out of your Command Station. The manual that came with your command station will explain how to use the OPSW's (Op Switches). Note that this proceedure will erase all consist information that is stored in the command station. (Universal Consists).

Advanced Slot Management

  1. Command Station Reset: Set to factory default by closing OpSw 39. CAUTION: This will clear the “Route Table’' (DCS 100/200) if in use. It will also clear the Alias Locomotive Roster (DCS 100/200). Alias Addressing requires a DT-100 throttle and is rarely used today.
  2. DCS100/DT200 Losing OpSw Settings: These command stations use a CR2032 coin cell to maintain their Random Access Memory which stores these and other parameters. If the cell is dead, all settings will be lost when the command station is shut down. Instructions for changing the cell are in the command station manual. The CR2032 cell and equivalents are commonly available. The command station requires one cell, there may be two cell holders, the empty one allows you to install a new cell before removing the old one, thus maintaining your settings. Do not install two cells as it is unnecessary.

Dropped Due To Slot Reservation Cs 1.6 Que Significa Se

Many erroneously refer to the memory in the command station as CMOS, and say they replaced the CMOS battery.

Expanded Slots

The DCS240 command station offers an additional range of slots, called Expanded Slots. These slots are only accessible to the DT402R2 throttle. Legacy throttles can only access up to 120 slots. The DCS240 handles this automatically by identifying the throttle type. The DCS240 offers up to 400 slots in this manner, instead of the typical 120 slots offered by other command stations.

The expanded slots are useful if a lot of consists are running. When building a consist using the expanded DT402 throttle the consist will be stored in the expanded slots.

When controlling a consist, the top loco address controls the consist. If the consist is selected by a legacy throttle, the DCS240 will move the top loco address to the standard slot range, making a link to the other loco addresses stored in the expanded slot range. This will leave as many of the standard slots available as possible.

Computer Interface and Software

If you have a computer interface for your DCC system there are software products that allow you to see a list of all the slots on your command station, and indicate the status of each slot. Some also give you the capability to free slots with the click of a mouse button.

The free JMRI software (JMRI website) contains the Slot Monitor which provides this functionality.

Purging Made Easy

From an email written by Don Crano on the Digitrax mailing list at Yahoo Groups.

Changes in Slot Status

If the slot status changes, or is purged by the system to be used by another decoderaddress, it does not mean all the data is cleared from the slot, only the status flag has changed, the data stays there to either be re-used by another LocoNet device (COMMON), or purged so new data can overwrite the existing data (IDLE).

Purge Timer

Each slot has a purge timer, but that timer is not always active, this will only happen when certain criteria is met.

How it all works:

When a LocoNet device (Throttle) is maintaining a SLOT in the refresh stack it will be required to check that the SLOT status matches its internal state before reusing any SLOT. If a device disconnects from the LocoNet and does not access a slot within the system's PURGE time, the Master (Command Station) will force the unaccessed SLOT to 'COMMON' status so other system devices can use the SLOT.
Typical purge time of a Master is from 200 to 600 seconds. Slot update activity is about every 100 seconds, i.e. if a user makes no change to a throttle/slot within 100 seconds, the throttle/device should automatically send a speed update at the current speed setting to reset the Purge timeout for that Slot.
Note that with a LocoNet wireless throttle, (IR/Radio) you can see the ping or update being sent while the throttle is in Power Save mode, it will wake up, send ,then go back to PS approximately every 60 seconds. This prevents the system from releasing that address and making it available to another throttle.
Before an address will be purged, the following criteria must be meet.
  1. The decoder's speed data must be at '00' or the Master (Command Station) must be set to force '00' speed upon purge.
  2. Any slot with the UP-CONSIST flag set will never be purged. This indicates the slot/decoder address is part of a consist. Prevents a locomotive from being purged while in operation as part of a consist.

Operator Discipline

Before removing a throttle from the layout:

  1. Un-Link consists, that clears the UP=CONSIST flag.
  2. Make sure all addresses associated with the throttle are at speed '00' (stopped with the throttle closed) and/or have the Master set to reset speed to zero when the slot is purged.
  3. Release or Dispatch any addresses associated with the throttle.

The above steps go a long way to keeping the FF or Slot=Max status from showing up.

The term UniVersal is a Digitrax registered trade mark. It is used to name or describe their command station assisted consisting. Digitrax actually uses what is called Unified Consisting, the system allows three modes of consisting, Advanced, Basic, and UniVersal, and may be mixed,matched, and even nested inside other consists. It is Unified because it can be done automatically without user intervention as they set up the consist.

Option Switch Notes

Consult the manuals for your system to determine the correct option switches for your command station.

Dropped due to slot reservation cs 1.6 que significa es

OPSW 13 changes purge time from 600 to 200 seconds. Good for faster, more rapid purges, bad for tetheredthrottles, as when an operator unplugs a non-wireless throttle from the LocoNet they now have 200 seconds to plug in elsewhere. OPSW 14 can completely stop purging from happening.

OPSW 15 controls the speed value, can be set to force speed value to 00 upon purge. This prevents runaways from happening should an address be purged while a train is in motion.

Slot Following

Slot Following refers to operation of a stolen locomotive. When this happens the throttle will click every time the remote throttle initiates a speed change. The display will also change to indicate what is happening.

This feature allows two DT throttles to control a single address. Both throttles will show the speed and direction on their displays. This can be useful for training operators, allowing the mentor to take control without having to take the throttle physically from the operator.

Another application is computer control: A computer running CTC and routing control programs on Loconet can provide some automatic control over the train. It can change speed or stop the engine, while letting the engineer holding the throttle know what is happening.

Operating a on a DT40X Throttle

When the command station detects that a loco address that is in-use on one of its throttles is being changed by another throttle or computer, it will cause the throttle to “click” every time it sees a remote throttle change its locomotive settings. If that locomotive is in the active throttle, its speed display will also show the changes. This is called slot following.

This allows two DT throttles to run a single locomotive address with both throttles able to send commands to the loco. Both throttles will show the current speed and direction of the locomotive in their displays.

Slot following is useful for training new operators. The supervisor can “steal” a locomotive that is selected on a trainee’s throttle & be able to “look over the trainee’s shoulder” and closely supervise that locomotive’s control. The supervisor can gain instant override control without having to physically “grab” the trainee’s throttle. This lets you have unskilled visitors participating and enjoying operations without too much anxiety for either party.

Slot following also allows a computer on LocoNet to run CTC & routing control programs with automated control over locomotives. The computer can control speed and stop engines automatically while letting the engineer with the throttle in his hand know what is happening.

Ghost Throttle

A ghost throttle is one that you are not aware of. It was used to steal control of the locomotive and is still active. Erratic operation is often the result, as the command station overrides your throttle using the ghost throttle settings.

Acknowledgements

Information on resetting command stations and other additional information is from the 'Slot=Max' document found in the Digtrax Yahoo Groups file area. Author unknown.

Email written by the late Don Crano in 2004 on purging.

Retrieved from 'https://dccwiki.com/w/index.php?title=Slots&oldid=20684'

Honestly I've had a shitload of problems already running Counter-Strike (1.6) lagfree. Important detail is that I'm trying to play wireless.
On XP, there was the Wireless Zero Configuration Service that was causing lagspikes (if you're on XP and having lagspikes, check that link 🙂 ).
Now that I am on Windows 7, I'm not sure what to look for. I've done a clean OS install, updated my video card drivers, wlan drivers, but to no avail.

Que

When enabling 'net_graph 1' in the Counter-Strike console, I get the following result. The left side is during normal gameplay (a straight green line), and on the right there's a bouncy, interrupted line.

I've set my cvars to:

These are the vars I like, I'm just telling them for information.

I've taken the following steps in the hope to reduce the lagproblems,
I hope something of this will work for you:

1. Disabling MMCSS

Multiple forums stated that the lagspikes could be caused by the Multimedia Class Sheduler service.
Run regedit and remove in the entry DependOnService the line that says 'MMCSS'.

You will have to reboot after this. But try the rest of the proposed fixes first to save some time.

2. Disable Network Throttling

Because multimedia programs require more resources, the Windows networking stack implements a throttling mechanism to restrict the processing of non-multimedia network traffic to 10 packets per millisecond.

This implies that we should set the rate a bit higher to allow more packets. This seems a bit irrelevant, but I did it anyway.
Modify the following key in your registry, set NetworkThrottlingIndex to FFFFFFFF (hex) or 4294967295 (dec):

(thanks to stranger for pointing out that it had to be FFFFFFFF instead of FFFFFF)

3. Nagle's algorithm

Beyond the obvious settings in Windows or on your router, here’s a list of tweaks that may help quite a bit. It involves disabling Nagle’s algorithm, also commonly known as TCP no delay, which is basically an optimization of network traffic that tries to reduce overall packet volume but can cause extra latency in the connection. This should work on Windows 7 or Vista, though the same principle can probably applied to other operating systems as well.

Reservation

Dropped Due To Slot Reservation Cs 1.6 Que Significa Es

Go to the registry key for your network interface card, it's one of the {XXXX-XXXX-XXXX-XXXX}. Look for one that has 192.168.x.x in it.

Add a new DWORD 32-bit value here, name it TcpAckFrequency, then set it to 1. Do the same for TCPNoDelay.
This step would require a reboot also. (This is why you shouldn't have rebooted earlier lol.

4. Disable IPv6

In the Network and Sharing Center, change the adapter settings of the connection you're using (Properties).
On the Networking tab, remove the tick from the IPv6 box. If there's no difference, you can always tick it again.

References:

http://windows7forums.com/windows-7-games/22315-problem-latency-counter-strike-1-6-a.html
http://social.answers.microsoft.com/Forums/en-US/w7network/thread/af7aaf26-c5e3-478c-b1b8-2b1443d1306b
http://lifeandcode.net/2009/05/reduce-game-network-latency-in-windows-7-or-vista/